What the charger lights mean
Start with the lights. This table is from Ryobi's manual for the P118 18V ONE+ charger. Other chargers use different codes, so check the label on yours.
| Red light | Green light | What it means | What to do |
|---|---|---|---|
| On | Off | Ready, no battery in | Push the battery in until it clicks |
| Flashing | Off | Battery too hot or too cold | Wait. It starts charging on its own |
| Fading | Off | Battery or charger defective | Reseat once, then do the swap test |
| On | Flashing | Charging | Leave it |
| Off | On | Fully charged | Take the battery off |
| Off | Fading | Full, charger in energy save mode | Take the battery off |
| Off | Off | No power | Check the outlet and the cord |
Ryobi's multi-port chargers use other patterns. Ryobi support says both lights flashing on those means a defective battery or charger.
Fixes by what the charger shows
Flashing red: too hot or too cold
The charger is protecting the battery. Ryobi's manual says charging starts on its own once the pack cools down or warms up.
- Hot pack after hard use: leave it in the charger, out of the sun. Don't put it in the freezer.
- Cold pack from a truck or garage: bring it indoors. Ryobi support gives room temperature as 10 to 37 °C (50 to 99 °F).
Our guide to batteries in a cold garage covers winter storage.
Nothing happens: a deeply drained pack
If a pack sat empty for a long time, the charger first gives it a slow pre-charge. The manual says it switches to normal charging once the voltage comes back up. Leave it on the charger in a room-temperature spot before you give up on it.
Fading red: defective pack or charger
Follow Ryobi's steps in order:
- Take the battery out and put it back in once.
- If the light fades again, try a different battery.
- If the second battery charges, the first pack is bad.
- If the second battery also shows a fault, the charger may be bad.
That's the swap test. It's the fastest way to tell a bad battery from a bad charger.
No lights at all
- Plug something else into the outlet to check it has power.
- Unplug the charger and look at the cord, plug and charger for damage. Ryobi says not to use a damaged charger.
- With the charger unplugged and the battery out, wipe dust from the terminals with a dry cloth.
- Plug in again. The red light should come on with no battery in it.
Myths that don't work (or aren't safe)
| Myth | The facts |
|---|---|
| "Hold the button for 15 seconds to reset it." | There is no reset button. The button on many ONE+ packs is a fuel gauge. Ryobi's charger manual gives no such step. |
| "Put it in the freezer." | A cold pack won't charge. The charger waits until it warms up. |
| "Jump it from a good battery with wires." | This bypasses the charger's checks. The CPSC warns never to use a lithium-ion pack that has been modified or reworked. |
| "Open it and replace the cells." | Same CPSC warning: never use packs rebuilt with used or repurposed cells. |
| "Any 18V charger will do." | The CPSC advises using the charger the maker supplies or recommends. |
If that didn't work
- The pack charges but dies fast. It's likely worn out. Check its capacity with a known load, or compare runtime with a newer pack. Our battery runtime calculator shows what runtime to expect.
- One tool won't run but the pack charges. Try the pack in another tool. If it works there, the first tool is the problem.
- The charger shows a fault with every pack. Replace the charger. Use a Ryobi charger made for your battery type.
The charger light codes page compares Ryobi with other brands.
When to stop and get help
- Damaged packs: The Battery Network (formerly Call2Recycle) says swollen, leaking, punctured or overheating lithium-ion batteries must not go in the trash, home recycling or store drop-off boxes. Ask Ryobi or your local hazardous waste site how to dispose of them.
- Worn-out but undamaged packs: Recycle them at a battery drop-off. Tape the terminals or bag each pack first.
- Under warranty: Ryobi lists a 3-year warranty for 18V ONE+ products. Contact Ryobi support with your receipt.
Keep packs healthy
- Let a hot pack cool before charging.
- Store packs indoors, at room temperature.
- Ryobi's manual says to take the pack off the charger once it's full.
- Keep a spare pack so you're not stuck mid-job.
All our Ryobi guides are on the Ryobi brand page. New to the platform? Read is Ryobi a good brand and our guide to power tool battery platforms. More battery and power guides are in the electrical hub.
What you'll need
- A second Ryobi battery of the same voltage: For the swap test
- Your charger's model number: On the label underneath; light codes vary by model
- Dry, lint-free cloth: To wipe dust off the terminals, with the battery out and the charger unplugged
- Proof of purchase: For a warranty claim
Key takeaways
- Read the charger lights before anything else. On Ryobi's P118 18V charger, flashing red means too hot or cold; fading red means a defective pack or charger.
- Hot or cold packs charge on their own once they reach a safe temperature. Ryobi support gives room temperature as 10 to 37 °C (50 to 99 °F).
- Swap test: if a second battery charges, the first pack is bad. If both show a fault, the charger may be bad.
- There's no button reset. Don't jump a pack from another battery, freeze it or open it. CPSC warns against reworked lithium-ion packs.
- A swollen, leaking, hot or smelly pack is done. Stop using it and don't put it in a store drop-off box. Ask Ryobi or your local hazardous waste site.
Questions people ask
Why is my Ryobi battery flashing red on the charger?
On the P118 charger, a flashing red light with the green off means the pack is too hot or too cold. The charger waits, then starts charging on its own once the pack reaches a safe temperature. Leave it in the charger in a room-temperature spot.
What does a fading red light mean on a Ryobi charger?
On the P118, a fading red light means the battery pack or the charger is defective. Take the battery out and put it back once. If it fades again, try a different battery. If the other battery charges, the first pack is bad.
What does red and green flashing mean on a Ryobi charger?
It depends on the charger. On Ryobi's multi-port chargers, Ryobi support says both lights flashing means a defective battery or charger. On the P118, red on with green flashing means it's charging normally. Check the light table on your charger's label or manual.
How do you reset a Ryobi battery?
There is no reset button. The button on many ONE+ packs is a fuel gauge. Ryobi's charger manual gives two steps: remove and reinsert the pack, then try a different battery. Online tricks like holding the button or jumping it from another pack are not in Ryobi's instructions.
Can I jump-start a dead Ryobi battery with another battery?
We don't recommend it. Wiring packs together bypasses the charger's checks. The CPSC warns never to use lithium-ion packs that have been modified or reworked. If the charger can't wake a pack, replace it.
How long does a Ryobi battery take to charge?
Ryobi's P118 manual says about 1 hour, depending on the pack. Bigger packs take longer. A deeply drained pack first gets a slow pre-charge, so it can take longer to start.
Is my Ryobi battery under warranty?
Ryobi lists a 3-year warranty for 18V ONE+ products. Keep your receipt and contact Ryobi support or the store you bought it from.
Why won't my Ryobi 40V battery charge?
The same causes apply: heat, cold, a deeply drained pack or a worn-out pack. 40V chargers use their own light codes, so check the table in your 40V charger's manual before you swap batteries.
Sources
- P118 18V ONE+ charger operator's manual: LED table, hot/cold packs, defective pack steps, ~1 hour charge (Ryobi, via ManualsDir)
- P118 operator's manual, charging section: room temperature, energy save mode, remove when charged (Ryobi, via ManualsDir)
- How to troubleshoot a RYOBI charger that's not lighting or charging: 10 to 37 °C, swap test (RYOBI Australia support)
- Warranties: 18V ONE+ 3-year, 40V outdoor 5-year (RYOBI Tools support)
- Micromobility information center: use the supplied charger, never use modified or reworked battery packs (U.S. Consumer Product Safety Commission)
- Battery safety: damaged or defective lithium-ion batteries need special handling (The Battery Network, formerly Call2Recycle)
Change log: Nov 6, 2026: Rewritten from the 2023 archive post. Removed the 'hold the button 15 seconds' reset and the NiCd/NiMH filler; added the P118 light table, swap test, myth list and CPSC/Battery Network safety.